Worcester Bosch EA 229 fault code
The display on your Worcester Bosch is showing EA 229. Below: the meaning, the likely causes and the point at which to stop and call.
- Gas Safe registered engineers
- Written quote before any work
- Open six days a week
- Local to SW11, SW8 & SW18
What EA 229 means
EA 229 means the burner was lit but lost its flame while running. Condensate and flue problems are frequent causes. Some causes are simple to rule out, others need a Gas Safe registered engineer.
Meanings vary a little between models; your manual has the definitive list. London's hard water scales up heat exchangers over time, so we often find limescale playing a part in Battersea boilers that misbehave.
Common causes
The manufacturer's fault table and day-to-day experience point to:
- A frozen or blocked condensate pipe or trap
- An interruption in the gas supply
- A worn flame-sensing electrode
- Strong wind or an obstruction at the flue terminal
Safe checks you can do
1. Look for a frozen condensate pipe
The condensate pipe is the plastic pipe that carries water from the boiler to a drain, often outside. If it's frozen, the boiler may gurgle and then lock out. Only if the pipe is at ground level and easy to reach, thaw it with a warm cloth or warm (not boiling) water, then reset the boiler. Leave pipes at height to an engineer.
2. Glance at the flue terminal
From outside, check that nothing obvious is blocking the flue terminal, such as plants, a cover or a nest. Never take apart or adjust the flue yourself: any damage or blockage is a job for a Gas Safe registered engineer.
3. Rule out the gas supply
Check that your gas hob works. Prepayment customers should look at the meter still has credit, since a meter that has run out stops the boiler lighting. Leave the gas valve, pipes and anything behind the casing alone. If you smell gas, ring 0800 111 999 from outside the property.
4. Try a single reset
Use the reset button on the front panel: on a Greenstar, hold it for around five seconds. Allow a little time for the boiler to try again. If the same code comes back, stop resetting: repeated resets can hide a fault that needs proper attention.
Never remove the boiler casing or touch the gas valve, gas pipes or flue. If you smell gas, leave the property and ring the National Gas Emergency Service on 0800 111 999.
When to call a Gas Safe engineer
Repeat EA 229 lockouts call for an engineer: the trap sits inside the casing, which is engineer territory.
If it won't clear, call 020 3507 1048 or book a visit online. Our hours are Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.
Related codes
- Worcester Bosch EA 227: no flame detected at ignition
- Vaillant F.29: flame loss during operation
- Worcester Bosch D5: condensate pump fault (floor-standing)
- All Worcester Bosch codes
- Boiler breakdown help in Battersea
Questions
What's the difference between EA 227 and EA 229?
EA 227 means no flame was detected at ignition. EA 229 means the flame was established and then lost during operation.
Can you fix a Worcester Bosch boiler in Battersea?
We do. We work on Worcester Bosch boilers all over Battersea, from Latchmere to Queenstown Road. Call 020 3507 1048 with the code.