Gas Safe registered engineersMonday to Friday 7am to 7pm, Saturday 8am to 2pm, Sunday closed020 3507 1048
Call an engineer020 3507 1048

Battersea · Clapham Junction · Nine Elms

Worcester Bosch EA 227 fault code

Your Worcester Bosch has stopped and the display says EA 227. Below: the meaning, the likely causes and the point at which to stop and call.

Call 020 3507 1048 Book an engineer

  • Gas Safe registered engineers
  • Written quote before any work
  • Open six days a week
  • Local to SW11, SW8 & SW18

What EA 227 means

On a Worcester Bosch Greenstar, EA with cause code 227 is an ignition lockout: no flame was detected. Worcester's own guidance lists the gas supply, a frozen condensate pipe and a blocked flue outlet as things to check. Some causes are simple to rule out, others need a Gas Safe registered engineer.

Meanings vary a little between models; your manual has the definitive list. If you're in a flat near Between the Commons, it's worth knowing where your boiler's condensate pipe goes, because many run down an exposed outside wall.

Common causes

The manufacturer's fault table and day-to-day experience point to:

  • A blocked flue outlet
  • Gas off or a prepayment meter with no credit
  • A frozen or blocked condensate pipe
  • A gas valve or PCB fault
  • A worn ignition or flame-sensing electrode

Safe checks you can do

1. Make sure gas is reaching the house

See whether another gas appliance, such as the hob, lights. On a prepayment meter, look at the credit and any emergency credit, as running out is a common cause of ignition lockouts. Leave the gas valve, pipes and anything behind the casing alone. If you smell gas, ring 0800 111 999 from outside the property.

2. In freezing weather, look at the condensate pipe

Every modern boiler has a small plastic condensate pipe, and outdoor sections freeze in a cold snap. If it's frozen, the boiler may gurgle and then lock out. Provided you can reach the pipe safely from the ground, thaw it with a hot water bottle or warm, not boiling, water from a watering can, then reset the boiler. Don't try this at height.

3. Glance at the flue terminal

From outside, check that nothing obvious is blocking the flue terminal, such as plants, a cover or a nest. Don't touch, remove or alter any part of the flue: if it looks damaged or blocked, switch the boiler off and ring an engineer.

4. Reset the boiler once

Follow the reset steps in your manual: Worcester Bosch asks you to hold it for about five seconds. Give it a few minutes to run through its start-up. If it locks out again, don't keep pressing: repeated resets can hide a fault that needs proper attention.

Anything behind the casing, and any gas or flue work, must be left to a Gas Safe registered engineer. If there's a smell of gas, ring 0800 111 999 from outside.

When to call a Gas Safe engineer

When the simple checks don't clear it, the electrode, gas pressure and gas valve need testing: those tests involve the gas side of the boiler.

If it won't clear, call 020 3507 1048 or book a visit online. Our hours are Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.

Related codes

Questions

What does EA 227 mean on a Worcester Bosch?

No flame was detected when the boiler tried to light. Look at the gas supply, the condensate pipe and the flue outlet, then reset.

Can you fix a Worcester Bosch boiler in Battersea?

We do. We work on Worcester Bosch boilers all over Battersea, from Wandsworth Common to Battersea Square. Ring 020 3507 1048 and quote EA 227.

Call 020 3507 1048